Skyjack announces safety related recall and immediately stopping the using its Mast Weld Reinforcement Machines, models SJ12E, SJ16E, SJ20E.

On the identified machines, Skyjack has identified a quality issue with the weld between the mast base plate and mast vertical section. Failure to implement this bulletin may result in cracks developing along the weld between the mast base plate and the mast vertical section, potentially leading to structural failure of the vertical mast causing serious injury or death.

The units listed under “Affected Serial Numbers” must be immediately removed from service and have the mast section repaired as soon as possible. Skyjack requires that this bulletin be completed on all affected models with the listed serial numbers.

Serial Ranges:

  • SJ12E: A60 1000 906 through A60 1005 185
  • SJ16E: A60 1000 909 through A60 1005 478
  • SJ20E: A60 1000 763 through A60 1005 631